Dental Endodontic Continuous Wave Backfill Obturation System Gutta Percha Gun

$ 475.19

Availability: 100 in stock
  • Brand: DenJoy
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • UPC: 732140427705
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • Working temperature: 0°C-200°C
  • MPN: Does Not Apply
  • All returns accepted: Returns Accepted
  • Adapter Input: 100V-240VAC

    Description

    Cordless Continuous Wave Obturation
    3D obturation is critical in perfect root canal therapy as it gets high compaction to prevent leakage,
    entomb remaining bacteria and reduce the chance of reinfection. Denjoy's Free Fill obturation
    system was designed to be used with the continuous wave warm vertical compaction technique. Its
    cordless design gives dentists the freedom and flexibility to perform predictable high quality 3D
    endodontic obturation without cords or wires getting in the way
    Preparation
    1. Master Cone Fit.
    Select same gutta-percha point as previous used the final NITI file
    Confirm tugback, insert the master cone to the exact WL and fell for a"tug
    if there is no appropriate tugback, cut around 0.5mm to try again
    Nornally, cut 0. 5mm for straight root canal but not for curved one
    2, Hand Plugger Fit
    Prepare 2-3 hand pluggers to condense, for the first plugger, select the
    appropriate one that reaches around -5mm, others are 5mm by 5mm from the
    WL until the orifice
    3, Heated Plugger Fit:
    Select the appropriate one that can be inserted to at least 4-6mm short of WL,
    then preset the rubber stopper(To prevent burns, confirm that the power is
    off before inserting the heated plugger
    Deep Downpack:
    Step 1: Apical Third Condensation: Insert the master cone
    to the exact WL coated with sealer, use a gentle pumping
    action to sure that the root canal walls are full of sealer
    Step 2: Adjust to the desired temperature according to the
    selected heated plugger, activate the operating switch, cut
    off the excess cone at the orifice level. and then condense
    the gutta-percha with selected hand plugger vertically and
    slightly
    Step 3: Set the heated plugger on the cone vertically,
    activate the operating switch while push towards the
    apex. Stop when you get to the marked working leghth
    continue to exert apical pressure until the cone cools
    (Notice: complete the whole process less than 4 seconds)
    Step 4: Hold in place for 10 seconds without heating, give
    a 1-second burst of heat, and hold on for another 1-second
    without heat, then pull from canal. Use pre-selected hand
    plugger to condense the apical 1/3rd and lateral canals
    Obturator Backfill:
    Step 1: Turn on the obturator and wait
    until the preset temperature is reached
    insert the iniection needle unitl it contacts
    the cut section of the cone. wait 5 seconds
    to allow the apical fill to soften slightly
    Step 2: Incremental injection, pull the
    trigger to fill the canal 3-4mm, draw
    back the injection needle slowly during
    the backfill
    Step 3: Use the selected hand plugger
    to condense the backfilled gutta-percha
    Immediately
    Step 4: Reinsert the needle, hold in
    place for 5 seconds to soften slightly,
    and re-backfill until apical foramen
    then repeat step 3